High-Sensitivity Troponin

HS TNT
Description
"High-Sensitivity Troponin" test detects very small amounts of troponin, a protein released into the blood when the heart muscle is damaged. Doctors often order this test when symptoms suggest a heart attack or myocardial stress. Even slight elevations may indicate early cardiac injury, inflammation, or chronic disease risk. Results guide urgent care, monitor treatment, and assess long-term cardiac risk. Its sensitivity makes it a powerful tool for early diagnosis and long-term heart health monitoring.
Test Category
Proteins
Procedure
Invasive
Sample Type
Blood – Plasma
Units
Nanograms Per Liter
Procedure Category
Blood Draw
Test Group
Cardio Risk Group
Test Group Description
Cardio Risk Group: This group focuses on assessing various markers associated with cardiovascular health and risk factors, aiding in the early detection and management of cardiovascular diseases.
Optimal Range
For All Individuals:
Conventional Unit: <13.00 ng/L
SI Unit: <13.00 ng/L
Normal Range
For Men:
Conventional Unit: <22.00 ng/L
SI Unit: <22.00 ng/L
For Women:
Conventional Unit: <14.00 ng/L
SI Unit: <14.00 ng/L
Results That Differ From The Norm (Direct and Indirect Causes)
Increased levels may indicate:
Angioplasty (Procedure to widen narrowed or obstructed arteries)
Cardiomyopathy (Disease of the heart muscle)
Coronary artery bypass grafting (Surgical procedure to improve blood flow to the heart)
Coronary artery disease (Narrowing or blockage of coronary arteries)
Heart failure (Inability of the heart to pump blood effe...
Key Reasons For Testing
Cardiac Injury Detection: High-sensitivity troponin identifies myocardial injury, aiding in diagnosing acute coronary syndromes like heart attacks.
Risk Assessment: Elevated levels guide risk categorization and treatment decisions.
Myocardial Infarction Diagnosis: Essential for diagnosing heart attacks, enabling prompt intervention.
Prognostic Value: Provides insights into cardiac event severity, influenci...
Health Status Conditions It May Be Used To Assess
Currently, this test is not directly associated with any conditions listed on the Health Status page. However, it may be included as part of a broader set of tests linked to specific health conditions.
Some Prominent Medical Labs That May Offer This Test
Please note that this particular test has not been associated with any of the listed prominent medical labs. We recommend enquiring with your private physician or nearest hospital to determine where this specific test can be performed.
References
Important Note
Any medical procedure yielding results outside the norm may be directly or indirectly linked to the conditions outlined on this page. Various factors, including genetics, medication and supplement usage, recent illnesses, pregnancy, pre-test eating, smoking, and stress, can impact the test's outcome. Additionally, factors like false positives, false negatives, inaccurate analyses, and others can influence results.
Reference ranges, which help healthcare professionals interpret medical tests, may vary depending on age, gender, and other factors. They may also differ between laboratories due to variations in instruments and methods used. Optimal ranges are designed for preventive purposes, aiming to identify trends and potential risks early, while normal ranges reflect conventional laboratory values indicating no current disease or pathology. Your healthcare practitioner may have specific reasons for testing that deviate from the usual or may interpret results differently based on individual circumstances. Proper interpretation typically involves considering clinical findings and other diagnostic tests. Hence, it is crucial to provide your healthcare professionals with a comprehensive medical history, consult with them for result interpretation, and follow their guidance for potential re-testing or additional diagnostics.
Disclaimer
This content is provided solely for informative and educational purposes. It is not intended as a substitute for medical advice or treatment from a personal physician. Regarding the interpretation of their medical test results and/or specific health questions, it is recommended that all readers and viewers consult their physicians or other qualified health professionals. The publisher is not responsible for any adverse health effects that may result from reading or following the information in this educational content. Before beginning any nutrition, supplement, or lifestyle program, all viewers, especially those taking prescription or over-the-counter medications, should consult their physician or health care practitioner.
Please note that while prominent lab names are included in this content, we cannot guarantee that these labs offer all the tests mentioned. For confirmation, individuals should contact the labs directly or consult their medical practitioners. The information provided reflects general knowledge at the time of publication and may not include recent updates or emerging research. Readers should verify details with qualified professionals to ensure the most up-to-date and accurate guidance.
[1] Thygesen K, Alpert JS, Jaffe AS, et al. Fourth universal definition of myocardial infarction (2018). J Am Coll Cardiol.2018;72(18):2231-2264.
[2] Chapman AR, Lee KK, McAllister DA, et al. Association of high-sensitivity cardiac troponin concentration with cardiac outcomes in patients with suspected acute coronary syndrome. JAMA. 2017;318(19):1913-1924.
[3] Giannitsis E, Kurz K, Hallermayer K, Jarausch J, Jaffe AS, Katus HA. Analytical validation of a high-sensitivity cardiac troponin T assay. Clin Chem. 2010;56(2):254-261.
[4] Sandoval Y, Smith SW, Thordsen SE, et al. Diagnostic performance of high-sensitivity cardiac troponin T strategies and cardiac troponin I for early rule out of myocardial infarction. Am Heart J. 2012;163(3):369-376.
[5] Zhelev Z, Hyde C, Youngman E, et al. Diagnostic accuracy of single baseline measurement of Elecsys troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ. 2015;350:h1533.
[6] Zeller T, Tunstall-Pedoe H, Saarela O, et al. High population prevalence of cardiac troponin I measured by a high-sensitivity assay and cardiovascular risk estimation: the MORGAM Biomarker Project Scottish Cohort. Eur Heart J.2014;35(5):271-281.
[7] Shah AS, Anand A, Sandoval Y, et al. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet. 2015;386(10012):2481-2488.
[8] Eggers KM, Jaffe AS, Lind L, et al. Prognostic value of high-sensitivity cardiac troponin T levels in the elderly. Clin Biochem. 2013;46(12):1163-1168.
[9] Neumann JT, Sörensen NA, Schwemer T, et al. Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm. JAMA Cardiol. 2016;1(4):397-404.
[10] Apple FS, Collinson PO. Analytical characteristics of high-sensitivity cardiac troponin assays. Clin Chem.2012;58(1):54-61.
[11] Mills NL, Lee KK, McAllister DA, et al. Implications of lowering the threshold of plasma troponin concentration in diagnosing myocardial infarction: cohort study. BMJ. 2012;344:e1533.
[12] Mueller C, Giannitsis E, Christ M, et al. Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction using high-sensitivity cardiac troponin T. Ann Emerg Med. 2016;68(1):76-87.e4.
[13] deFilippi CR, de Lemos JA, Christenson RH, et al. Association of serial measures of cardiac troponin and N-terminal pro-B-type natriuretic peptide with incident heart failure and cardiovascular death in older adults. JAMA.2010;304(22):2494-2502.
[14] Body R, Carlton E. Understanding cardiac troponin part 1: avoiding troponinitis. Emerg Med J. 2018;35(2):120-125.
[15] Reichlin T, Schindler C, Drexler B, et al. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Arch Intern Med. 2012;172(16):1211-1218.
[16] Westermann D, Neumann JT, Sörensen NA, et al. High-sensitivity assays for troponin in patients with cardiac disease. Nat Rev Cardiol. 2017;14(8):472-483.
[17] Januzzi JL Jr, Mahler SA, Christenson RH, et al. Recommendations for institutions transitioning to high-sensitivity troponin testing. J Am Coll Cardiol. 2019;73(9):1059-1077.